HRV Cool Plus™

Offering extra protection against overheating

The Titon HRV Cool Plus™ offers a solution designed to deliver cooling, filtered air for user comfort in warmer weather conditions. It seamlessly integrates into heat recovery ventilation systems, boasting easy installation, intuitive control and effortless maintenance.

NBS Source logo

Equipped with an integrated cooling module, the HRV Q Plus/MVHR system enhances its performance by pre-cooling incoming fresh air during warmer months. By merging improved air quality and energy efficiency, MVHR systems with cooling modules greatly aid in creating sustainable and comfortable indoor environments, while also aligning with Approved Document O (ADO) guidelines by recycling energy within a home.

TP762, TP759, TP761

Features & Benefits

  • Up to 3.0 kW total cooling capacity (dependent on airflow rate and relative humidity)
  • Suitable for wall mounting, floor mounting, or installation above a washing machine. When wall-mounted, the supporting structure must be capable of carrying the combined weight of the cooler, MVHR unit, and mounting bracket (100 kg wall-mounted / 108 kg floor-mounted).
  • The unit features a fully sealed refrigerant heat pump with coil and fin heat exchangers, requiring minimal maintenance—comparable in operation to a domestic refrigerator or freezer. Designed for proven reliability.
  • Uses R32 refrigerant (Global Warming Potential, GWP: ~675).
  • The heat cell provides cooling assistance by pre-conditioning incoming fresh air during operation, functioning in a similar manner to its standard heat recovery process.
  • Designed for installation below ceiling level within the heated space, while remaining compact enough to allow placement of a washing machine beneath.
  • Configurable for right or left hand installation on site.
  • Port diameter: 160 mm
  • CIBSE accredited CPD course available on Part O

 

Technical Information

Product Codes and Specific features

Operation Cycle

  • Pre-set temperature inside the dwelling is reached
  • MVHR increased speed to cooler boost
  • Once achieved the cooler will start
  • Pre-set tempered internal temperature reached
  • Cooler will deactivate
  • MVHR decreased to continuous levels

Additional Controls

  • Optional manual mode via the onboard aura-t™
  • Minimum atmosphere temperature controls to ensure the cooler doesn’t operate with the dwelling heating system
  • Cooler can be deactivated via the thermostat and/or onboard aura-t™

How

  • Thermostat in Cooling Mode
  • MVHR atmospheric temperature sensing
  • Sufficient airflow for cooling operation automatically set by our controls
  • Internal pressure sensors ensure cooler operates only when sufficient airflow is maintained
  • Active communication between MVHR and Cooler

Technical Information

HRV Cool Q Plus™ - TP762
Includes: Cooler, MVHR and Flexible Silencer

Mount:
Wall mounted unit - TP759
Floor mounted unit - TP758
Floor washing machine mounted unit - TP761
(Unhanded and handing configured at installation)

Filters:
ISO Coarse 85% (G4) filters fitted as standard.

Pack requirements

  • Cooler enabled HRV Q Plus MVHR
  • HRV Cool Plus™ cooler
  • Connection silencer ducts x 4
  • Room Thermostat
  • Wall mounting bracket or Floor standing bracket
  • Middle duct cover

Accessories

  • Cooler top duct cover
  • HRV Drain Cover

 

Please note that the room thermostat will be in the packing for the HRV MVHR and that the ‘Duct cover’ will be part of the mounting kits.

Standards

Conforms to requirements of UK statutory Building Regulations and Technical Standards for Ventilation and BRE 398.
Meets requirements of Building Regulations Approved Document O (England & Wales).

EU RoHS Directive compliant.

Conforms to requirements of EC council directives relating to Electromagnetic Compatibility and Electrical Safety:
2006/95/EC (LVD), 2004/108/EC (EMC)
EN 60335-1:2002/A2:2006, EN 60335-2- 80:2003/A1:2004.
CE and UKCA marked.

Specification

Dimensions:
Wall mounted: 704mm (W) x 518mm (D) x 1550 (D) (excluding ports).
Floor mounted: 704mm (W) x 518mm (D) x 2002 (H) (excluding ports).
Floor washing machine mounted: 704mm (W) x 518mm (D) x 2296 (H) (excluding ports).

Weight: Wall mounted 100 kg, Floor mounted 108 kg
Finish: White Paint (RAL9016 Semi-gloss Traffic White)

Materials:
Housing: Zintec sheet steel housing, powder coated white
Internals: Expanded polypropylene (EPP)
Heat exchanger: Made from high quality PET materials
Internal insulation: Closed cell foamed Nitrile rubber, class ‘O’ fire rating
Standard filters: Grade ISO Coarse 85% (G4) synthetic filters.

Electrical:
HRV Unit: 230V ~ 50/60Hz, 5A fuse
Cooler: 230V ~ 50/60Hz, 8A fuse

Installation: To be installed accordance with the relevant and applicable building regulations.

Maintenance: Service and filter clean/replacement subject to local environment - see product manual.

Acoustics: Full acoustic data available online www.titon.com/HRV_Cool_acoustics.

Air Performance

Preliminary Tempering Performance

db 29 wb 21.2 - External Air Temperature

Conditions  Cooling (kW) /
Airflow Rates (l/s) 
60 70 80 90 100 110 120
23°C Internal Combined Total kW 1.75 1.94 2.12 2.28 2.42 2.56 2.68
Combined Sensible kW 1.26 1.42 1.57 1.72 1.87 2.01 2.14
Supply air °C 11.6 12.2 12.7 13.1 13.5 13.9 14.2
24°C Internal Combined Total kW 1.70 1.88 2.04 2.19 2.33 2.46 2.58
Combined Sensible kW 1.23 1.39 1.54 1.69 1.83 1.96 2.10
Supply air °C 12.0 12.5 13.0 13.4 13.8 14.2 14.5
25°C Internal Combined Total kW 1.64 1.81 1.97 2.11 2.24 2.36 2.47
Combined Sensible kW 1.20 1.36 1.51 1.65 1.79 1.92 2.05
Supply air °C 12.3 12.9 13.4 13.8 14.2 14.5 14.8
26°C Internal Combined Total kW 1.58 1.75 1.89 2.03 2.15 2.26 2.36
Combined Sensible kW 1.18 1.33 1.47 1.61 1.75 1.88 2.01
Supply air °C 12.7 13.2 13.7 14.1 14.5 14.8 15.1

db 32 wb 23.7 - External Air Temperature

Conditions  Cooling (kW) / Airflow Rates (l/s)  60 70 80 90 100 110 120
23°C Internal Combined Total kW 1.93 2.15 2.36 2.55 2.73 2.90 3.06
Combined Sensible kW 1.30 1.48 1.65 1.81 1.97 2.13 2.28
Supply air °C 14.0 14.4 14.9 15.3 15.6 15.9 16.2
24°C Internal Combined Total kW 1.87 2.09 2.28 2.47 2.64 2.80 2.95
Combined Sensible kW 1.28 1.45 1.62 1.78 1.94 2.09 2.24
Supply air °C 14.3 14.8 15.2 15.6 15.9 16.2 16.5
25°C Internal Combined Total kW 1.81 2.02 2.21 2.39 2.55 2.70 2.84
Combined Sensible kW 1.25 1.43 1.59 1.75 1.90 2.05 2.19
Supply air °C 14.6 15.1 15.5 15.9 16.2 16.5 16.8
26°C Internal Combined Total kW 1.75 1.95 2.13 2.30 2.45 2.60 2.73
Combined Sensible kW 1.23 1.40 1.56 1.71 1.86 2.01 2.15
Supply air °C 15.0 15.4 15.8 16.2 16.5 16.8 17.1

db 34 wb 25.3 - External Air Temperature

Conditions  Cooling (kW) / Airflow Rates (l/s)  60 70 80 90 100 110 120
23°C Internal Combined Total kW 2.04 2.29 2.52 2.74 2.94 3.13 3.31
Combined Sensible kW 1.33 1.52 1.70 1.87 2.04 2.21 2.37
Supply air °C 15.5 16.0 16.4 16.7 17.1 17.4 17.6
24°C Internal Combined Total kW 1.98 2.22 2.45 2.65 2.85 3.03 3.20
Combined Sensible kW 1.31 1.49 1.67 1.84 2.01 2.17 2.33
Supply air °C 15.9 16.3 16.7 17.0 17.4 17.6 17.9
25°C Internal Combined Total kW 1.92 2.15 2.37 2.57 2.75 2.93 3.09
Combined Sensible kW 1.29 1.47 1.64 1.81 1.97 2.13 2.28
Supply air °C 16.2 16.6 17.0 17.3 17.6 17.9 18.2
26°C Internal Combined Total kW 1.86 2.09 2.29 2.48 2.66 2.82 2.98
Combined Sensible kW 1.26 1.44 1.61 1.78 1.93 2.09 2.24
Supply air °C 16.6 16.9 17.3 17.6 17.9 18.2 18.5

The combined total kW cooling accounted for coolth recovery, sensible and latent cooling. These results therefore reflect expected cooling power and supply air temperatures when in operation. For cooling output data based on your assumed external design conditions, please consult Titon.

Wall Mounted - Drawing & Dimensions

Floor Mounted - Drawing & Dimensions

Washing Machine Floor Mounted - Drawing & Dimensions

Resources

MANUALS & DOCUMENTATION

(11)
Loading resources...
Still have questions?

Our team is here to help get in touch today!

Call me back

Login

Basket