HRV1.35 Q Plus

Mechanical Ventilation with Heat Recovery unit (MVHR)

The enhanced capacity ultra compact HRV1.35 Q Plus continuously running whole-house ventilation unit with heat recovery is independently tested by the BRE and maintains an ultra compact size despite its improved airflow performance.

Combining extremely low power consumption and a highly efficient heat exchanger, this unit enhances SAP performance via Appendix Q, and yet remains versatile enough in size to be equally as functional in larger apartments as it is in small to medium sized dwellings.

Recognised and listed in the UK Product Characteristics Database and includes intelligent humidity options through controller options.

TP408HMB,TP408HMB_LT,TP418B2,TP418B2_T

Features & Benefits

  • Extremely low Specific Fan Power; down to 0.65 W/l/s
  • Highly efficient heat exchanger; up to 88%
  • Airflow up to 60l/s (217 m3/h) at 100 Pa
  • Accepts 125mm diameter ducting, no adaptors required

 

HMB and B2 Models

  • IP32 rating
  • Boost Overrun Timer
  • Boost Inhibit
  • Internal Humidity Sensor
  • Filter Change Alert
  • Four Fan Speeds
  • SUMMERboost®
  • Summer Bypass
  • Volt Free Switch Inputs (x3)
  • Frost Protection Program
  • Multiple Internal Temperature Sensors
  • Left or right handing onsite option available (delivered as LH as standard
  • On-Board and Off-Board Control Options (please refer to controls product page for more information)

 

B2 Models (only)

  • Dwelling Supply Air Comfort Control (reduces the amount of cold air being supplied to dwelling)
  • Dwelling Supply/Extract Protection
  • Balanced Frost Protection
  • Live Switch Inputs (x2)

Technical Information

Product Codes and Specific features

Product Codes and Specific Features

HMB Models:
Product Model Product Code Energy Rating
HRV1.35 Q Plus - HMB TP408HMB Energy Rating A
HRV1.35 Q Plus -HMB Eco auralite® Indicator
(onboard indicator)
TP408HMB_LT
B2 Models:
Product Model Product Code Energy Rating
HRV1.35 Q Plus - B2 TP418B2 Energy Rating A
HRV1.35 Q Plus - B2 aura-t™ Control
Indicator (onboard indicator)
TP418B2_LT

Filters:

ISO Coarse 55% (G3) filters - XP40032, fitted as standard
ISO Coarse 60% (G4) filters - XP46022, spares only

 

Standards

Conforms to requirements of UK statutory Building Regulations and Technical Standards for Ventilation and BRE 398.
SAP Appendix Q tested
Exceeds requirements of Building Regulations Approved Document L (England & Wales).
EU RoHS Directive compliant.
Conforms to requirements of EC council directives relating to Electromagnetic Compatibility and Electrical Safety:
2006/95/EC (LVD), 2004/108/EC (EMC), EN 60335-1:2002/A2:2006, EN 60335-2- 80:2003/A1:2004.
CE and UKCA Marked.

Specification

Dimensions: 600mm wide x 430mm high (excluding ports) x 285mm deep (295mm with mounting bracket).

Weight: 16kg.
Finish: White Paint (RAL9016 Semi-gloss Traffic White).

Materials

Housing: Zintec sheet steel housing, powder coated white.
Internals: Expanded polypropylene (EPP).
Heat exchanger: Polystyrene.
Internal insulation: Closed cell foamed Nitrile rubber, class ‘O’ fire rating.
Standard filters: Grade ISO Coarse 55% (G3) synthetic filters.
Guarantee period: 3 years (UK only).
Electrical: 230V ~ 50/60Hz, 3A fuse.
Installation: To be installed accordance with the relevant and applicable building regulations.
Maintenance: Service and filter replacement subject to local environment - see product manual.
Acoustics: Full acoustic data.

Performance

Exhaust terminal configuration*
Fan speed setting
Specific fan power (W/l/s)
Heat exchange efficiency (%)
Specific fan power (W/l/s)
Heat exchange efficiency (%)
2009
2012
Kitchen + 1 additional wet room
100% variable
0.65
88%
0.71
87%
Kitchen + 2 additional wet rooms
100% variable
0.69
87%
0.92
85%
Kitchen + 3 additional wet rooms
100% variable
0.84
85%
1.19
85%
Kitchen + 4 additional wet rooms
100% variable
1.04
84%
1.55
84%
Kitchen + 5 additional wet rooms
100% variable
1.25
84%
-
-
Kitchen + 6 additional wet rooms
100% variable
1.53
84%
-
-

Figures taken from the BRE Test Results.

*Number of wet rooms is based on SAP Q test criteria and does not correlate directly with regulatory performance requirements.

Performance Curve

*@FID (0 Pa)
All units offer 100% variable speed control.

Acoustic Data

Product
% of Max flow
Airflow
dB(A) @ 3m Hemispherical
dB(A) @ 3m Spherical
Induct Inlet
Induct Outlet
Casing Breakout
Casing Breakout
HRV1.35 Q Plus Eco
37%
22l/s @ 12Pa
28
39
19
16
65%
39l/s @ 38Pa
40
52
29
26
100%
60l/s @ 100Pa
47
61
36
33

All acoustic data is third party tested at Sound Research Laboratories (SRL) Ltd.