Contact Sales 0800 970 4190
The H200 Q Plus continuously running horizontal whole-house ventilation unit with heat recovery is independently tested by the BRE. It is ideal for flats due to its low profile.
Combining low power consumption and a highly efficient heat exchanger, this unit enhances SAP performance via Appendix Q and remains versatile enough in size to be equally functional in large through to small apartments alike.
The H200 Q Plus Range of MVHR unit comes in two different models; the ‘HMB’ & ‘B’ models which are part of our Eco version range. Each set out to accommodate our customers’ needs.
The H200 Q Plus comes in Eco versions only with a 100% airflow diverting Summer Bypass, recognised and listed in the UK Product Characteristics Database. They also include intelligent humidity options and can be fitted with the auralite® status indicator, aura-t™ (HMB and B models), auramode® and aurastat® controllers (B models only).
HMB and B Models
B Models
| Product Model | Product Code | Energy Rating |
| H200 Q Plus HMB Eco auralite® & aura-t™ ready - 204x60 |
TP451HMB | Energy Rating A |
| H200 Q Plus HMB Eco auralite® & aura-t™ ready - Ø160 |
TP453HMB | Energy Rating A |
| H200 Q Plus HMB Eco auralite® & aura-t™ ready - Ø150 |
TP452HMB | Energy Rating A |
| Product Model | Product Code | Energy Rating |
| H200 Q Plus B Eco-aura controls ready - 204x60 |
TP461B/ TP461BC (Cold Climate Option) |
Energy Rating A |
| H200 Q Plus B Eco-aura controls ready - Ø160 |
TP463B/ TP463BC (Cold Climate Option) |
Energy Rating A |
| H200 Q Plus B Eco-aura controls ready - Ø150 |
TP462B/ TP462BC (Cold Climate Option) |
Energy Rating A |
XP2010173– ISO Coarse 85% (G4) filter set fitted as standard.
XP2010174 - ISO ePM1 55% (F7) and ISO Coarse 85% (G4) filters available on request.
Conforms to requirements of UK statutory Building Regulations and Technical Standards for Ventilation and BRE 398.
SAP Appendix Q tested
Exceeds requirements of Building Regulations Approved Document L (England & Wales).
EU RoHS Directive compliant.
Conforms to requirements of EC council directives relating to Electromagnetic Compatibility and Electrical Safety:
2006/95/EC (LVD), 2004/108/EC (EMC), EN 60335-1:2002/A2:2006, EN 60335-2- 80:2003/A1:2004.
CE Marked.

Dimensions: 1000mm wide (excluding ports) x 200mm high x 600mm deep.
Weight: 32kg.
Finish: White Paint (RAL9016 Semi-gloss Traffic White).
Housing: Zintec sheet steel housing, powder coated white.
Internal insulation: Closed cell foamed Nitrile rubber, class ‘O’ fire rating.
Heat exchanger: aluminium.
Standard filters: Grade ISO Coarse 85% (G4) pleated panel filters.
Guarantee period: 3 years (UK only).
Electrical: 230V ~ 50/60Hz, 3A fuse.
Installation: To be installed accordance with the relevant and applicable building regulations.
Maintenance: Service and filter replacement subject to local environment – see product manual.
Acoustics: Full acoustic data.
|
Exhaust terminal configuration*
|
Fan speed setting
|
Specific fan power (W/l/s)
|
Heat exchange efficiency (%)
|
Specific fan power (W/l/s)
|
Heat exchange efficiency (%)
|
|
2009
|
2012
|
||||
|
Kitchen + 1 additional wet room
|
100% variable
|
0.58
|
83%
|
0.58
|
83%
|
|
Kitchen + 2 additional wet rooms
|
100% variable
|
0.55
|
83%
|
0.66
|
82%
|
|
Kitchen + 3 additional wet rooms
|
100% variable
|
0.61
|
82%
|
0.8
|
80%
|
|
Kitchen + 4 additional wet rooms
|
100% variable
|
0.72
|
81%
|
1.01
|
80%
|
|
Kitchen + 5 additional wet rooms
|
100% variable
|
0.85
|
80%
|
1.25
|
80%
|
|
Kitchen + 6 additional wet rooms
|
100% variable
|
0.99
|
80%
|
1.58
|
82%
|
|
Kitchen + 7 additional wet rooms
|
100% variable
|
1.2
|
80%
|
-
|
-
|
Figures taken from the BRE Test Results.
*Number of wet rooms is based on SAP Q test criteria and does not correlate directly with regulatory performance requirements.

*@FID (0 Pa)
All units offer 100% variable speed control
|
Product
|
% of Max flow
|
Airflow
|
dB(A) @ 3m Hemispherical
|
dB(A) @ 3m Spherical
|
||
|
Induct Inlet
|
Induct Outlet
|
Casing Breakout
|
Casing Breakout
|
|||
|
HRV200 Q Plus Eco
|
47%
|
39l/s @ 20Pa
|
25
|
37
|
25
|
22
|
|
64%
|
53l/s @ 37Pa
|
30
|
21
|
31
|
28
|
|
|
100%
|
83l/s @ 100Pa
|
39
|
54
|
41
|
38
|
|
All acoustic data is third party tested at Sound Research Laboratories (SRL) Ltd.