Contact Sales 0800 970 4190
The new CME3 Q Plus is ideal for continuous extract of stale, damp and polluted air to the outside environment.
The CME3 Q Plus is the latest addition to the centralised mechanical extract unit range. The combination of aesthetic smooth lines and a low profile makes it the ideal solution for hidden ceiling installation in flats and apartments.
The unit has a very large duty range over 104 l/s (376 m3/hr) at 200 Pa.
Switch live inputs
TP334HA – CME 3 Q Plus, humidity sensor (Full assembly).
Volt free switch inputs
TP332A – CME 3 Q Plus (Full assembly).
TP332HA – CME 3 Q Plus, humidity sensor (Full assembly).
Switch live inputs
TP334HA – CME 3 Q Plus, humidity sensor (Full assembly).
Conforms to requirements of UK statutory Building Regulations and Technical Standards for Ventilation and BRE 398.
SAP Appendix Q tested
Exceeds requirements of Building Regulations Approved Document L (England & Wales).
EU RoHS Directive compliant.
Conforms to requirements of EC council directives relating to Electromagnetic Compatibility and Electrical Safety:
2006/95/EC (LVD), 2004/108/EC (EMC) EN 60335-1:2002/A2:2006, EN 60335-2- 80:2003, A1:2004.CE Marked.
Other non-UK info available on request.
Dimensions (excluding ports):
310mm wide x 340mm long x 252mm high (excluding spigots)
Weight: 5 kg
Finish: Light grey / dark grey
Materials
Housing: Talc Filled Polypropylene
Guarantee period: 3 years (UK only)
Electrical: 230V ~ 50/60Hz, 3A fuse
Installation: To be installed accordance with the relevant and applicable building regulations.
Maintenance: See product manual.
Acoustics: Full acoustic data.
Exhaust terminal configuration*
|
Fan speed setting
|
Specific fan power (W/l/s)
|
Specific fan power
(W/l/s) |
2009
|
2012
|
||
Kitchen + 1 additional wet room
|
100% variable
|
0.18
|
0.18 |
Kitchen + 2 additional wet rooms
|
100% variable
|
0.16
|
0.16 |
Kitchen + 3 additional wet rooms
|
100% variable
|
0.17
|
0.17 |
Kitchen + 4 additional wet rooms
|
100% variable
|
0.19
|
0.19 |
Kitchen + 5 additional wet rooms
|
100% variable
|
0.21
|
0.21 |
Kitchen + 6 additional wet rooms
|
100% variable
|
0.25
|
0.25 |
Figures taken from the BRE Test Results apply for both the standard and humidity versions
*Number of wet rooms is based on SAP Q test criteria and does not correlate directly with regulatory performance requirements
Test results available for use with 100mm ducting.
Airflow
l/s |
% of
Max flow |
dB(A) @
3m Hemispherical |
dB(A) @ 3m Spherical
|
|
Induct
Inlet |
Casing
Breakout |
Casing
Breakout |
||
42 l/s
|
41%
|
19
|
21
|
18
|
69 l/s
|
65%
|
35
|
32
|
29
|
104 l/s
|
100%
|
44
|
45
|
42
|
Call me back