Contact Sales 0800 970 4190
The new CME3.1 Q Plus is ideal for continuous extract of stale, damp and polluted air to the outside environment.
The CME3.1 Q Plus is the latest addition to the centralised mechanical extract unit range. The combination of aesthetic smooth lines and a low profile makes it the ideal solution for hidden ceiling installation in flats and apartments.
The unit has a very large duty range over 113 l/s (405 m3/hr) at 200 Pa.
Switch live inputs
TP342HALS – CME3.1 Q Plus, humidity sensor and switch live inputs
Indicator Ready auralite® CME – TP517)
TP342CH – CME 3.1 Q Plus, humidity sensor, controls ready (Full assembly).
Volt free switch inputs
TP342A - CME3.1 Q Plus
TP342HA - CME3.1 Q Plus, humidity sensor
Switch live inputs
TP342HALS - CME3.1 Q Plus, humidity sensor and switch live inputs
Indicator Ready (auralite® CME - TP517)
TP342CH - CME 3.1 Q Plus, humidity sensor, controls ready (Full assembly).
Conforms to requirements of UK statutory Building Regulations and Technical Standards for Ventilation and BRE 398.
SAP Appendix Q tested
Exceeds requirements of Building Regulations Approved Document L (England & Wales).
EU RoHS Directive compliant.
Conforms to requirements of EC council directives relating to Electromagnetic Compatibility and Electrical Safety:
2006/95/EC (LVD), 2004/108/EC (EMC) EN 60335-1:2002/A2:2006, EN 60335-2- 80:2003, A1:2004.CE Marked.
Other non-UK info available on request.
Dimensions (excluding ports):
310mm wide x 340mm long x 252mm high (excluding spigots)

Weight: 5 kg
Finish: Light grey / dark grey
Materials
Housing: Talc Filled Polypropylene
Guarantee period: 3 years (UK only)
Electrical: 230V ~ 50/60Hz, 3A fuse
Installation: To be installed accordance with the relevant and applicable building regulations.
Maintenance: See product manual.
Acoustics: Full acoustic data.
| Exhaust terminal configuration* | Fan speed setting | Specific fan power (W/l/s) | Specific fan power (W/l/s) | 
| 2009 | 2012 | ||
| Kitchen + 1 additional wet room | 100% variable | 0.17 | 0.17 | 
| Kitchen + 2 additional wet rooms | 100% variable | 0.16 | 0.16 | 
| Kitchen + 3 additional wet rooms | 100% variable | 0.17 | 0.17 | 
| Kitchen + 4 additional wet rooms | 100% variable | 0.20 | 0.20 | 
| Kitchen + 5 additional wet rooms | 100% variable | 0.23 | 0.23 | 
| Kitchen + 6 additional wet rooms | 100% variable | 0.26 | 0.26 | 
Figures taken from the BRE Test Results apply for both the standard and humidity versions
*Number of wet rooms is based on SAP Q test criteria and does not correlate directly with regulatory performance requirements
Test results available for use with 100mm ducting.

| Airflow l/s | % of Max flow | dB(A) @ 3m Hemispherical | dB(A) @ 3m Spherical | |
| Induct Inlet | Casing Breakout | Casing Breakout | ||
| 42 l/s | 40% | 19 | 18 | 15 | 
| 71 l/s | 68% | 37 | 29 | 26 | 
| 105 l/s | 100% | 43 | 39 | 36 | 